SPECIFICATION | |||||||||||||
Product model | UP-8P8G-M2 | Product style | Solar on-grid inverter | photo |
| ||||||||
Body model | UP-8P8G-48 | Product specification | 500W/48VDC/230VAC | ||||||||||
1 | INPUT CHARACTERISTICS | ||||||||||||
1 | DC rated input voltage | 48VDC |
| ||||||||||
2 | DC input voltage range | 37—58VDC |
| ||||||||||
3 | DC input low voltage alarm | NO |
| ||||||||||
4 | DC input low voltage protection | 37±1VDC | 38±1.0VDC recovery | ||||||||||
5 | no-load input current | ≤0.1A | Standby | ||||||||||
6 | DC input high voltage protection | 58±1VDC | 56±1.0VDC recovery | ||||||||||
7 | Input insurance | 20A×1 |
| ||||||||||
8 | DC Input polarity reverse connect protection | Fusing |
| ||||||||||
2 | AC INPUT AND OUTPUT CHARACTERISTICS | ||||||||||||
1 | AC input voltage range | 195-253VAC |
| ||||||||||
2 | AC low voltage input protection | 195±5VAC | <2S | ||||||||||
3 | AC input low voltage recovery | 198±5VAC |
| ||||||||||
4 | AC input high voltage protection | 253±5VAC | <2S | ||||||||||
5 | AC input high voltage recovery | 249±5VAC |
| ||||||||||
6 | AC voltage frequency range | 50±1.0Hz |
| ||||||||||
7 | Over AC input frequency protection | <0.2S |
| ||||||||||
8 | AC output power factor(PF) | >0.9 |
| ||||||||||
9 | DC content in AC output current | <5% |
| ||||||||||
10 | Constant output power | 500±30W(constant) | Input voltage 48±0.5VDC | ||||||||||
11 | AC output fuse | AC250V 10A×1 |
| ||||||||||
3 | OTHER CHARACTERISTICS | ||||||||||||
1 | Recovery time for utility parameters beyond protection | ≥20S≤5Minute |
| ||||||||||
2 | Conversion efficiency (except wire loss) | ≥80% |
| ||||||||||
3 | Short circuit protection in output phases | YES |
| ||||||||||
4 | Island effects protection | <2S |
| ||||||||||
5 | Overheat protection | ≤75°C | Cooling fin temperature | ||||||||||
6 | Working temperature | -5--40°C |
| ||||||||||
7 | Storage temperature | -20--50°C |
| ||||||||||
8 | Working humidity | 10%--90% |
| ||||||||||
9 | Storage humidity | 5%--95% |
| ||||||||||
4 | FUNCTION STATE | ||||||||||||
1 | Working | The green is on, the red is off | |||||||||||
2 | DC output high/low voltage protection | The green is off,the red is flickering | |||||||||||
3 | AC output high/low voltage protection | The green is off,the red is flickering | |||||||||||
4 | Temperature protection | The green is off,the red is flickering |